1)Operation: Slider can be removed only after the locking screw(#10) is loosened 2)Basic Measuring Methods a: loosen the locking screw b: press "on" button, select sae or metric measurement bypressing "MM/INCH" Button. pressing "MM/INCH" button after measurement will display the sae/metric conversion c: to reset display to zero, close external measuring jaws,then press"zero" button....
Chat Now

Technical Specifications:


Measuring Range:0-150MM/0-6IN,0-200MM/0.8IN
Resolution0.01MM/0.0005IN
Accuracy

±0.02MM/0.001IN(<100MM)

±0.03MM/0.001IN(>100-200MM)

Repeatability0.01MM/0.0005IN
Max Measuring Speed1.5M/Sec, 60IN/SEC
Measuring SystemLinear Capacitive Measuring System
DisplayLCD display
Power:

One Alkaline Lithium Button Cell Battery 1.5V

,Type LR44 Capacity-180MAH

Working Temperature5℃-40℃/41 to 104 Degree F
Note:Accuracy affected in environements exceeding 80% relative humidity

Application:

1)Operation: Slider can be removed only after the locking screw(#10) is loosened

2)Basic Measuring Methods

a: loosen the locking screw

b: press "on" button, select sae or metric measurement bypressing "MM/INCH" Button.

 pressing "MM/INCH" button after measurement will display the sae/metric conversion

c: to reset display to zero, close external measuring jaws,then press"zero" button.


Maintenance Instructions:

  1. Keep the cailiper clean and dry(liquid can damage the slider)

  2. use a clean, dry cloth to clean all surfaces-do not use solvents or slvent based cleaners

  3. to save power , turn off the unit when not in use

  4. avoid contact with electrocy and or electronic devices


Battery replacement:

Flashing display indicates low battery. To replace battery, remove battery cover by sliding cover in the direction indicated and replace battery with positive side facing out.


Trouble shooting:

FaliureCauseMeasure
Display FlashesLow batteryReplace battery
Display does not change when slider is movedsystem lockedremove battery and replace after 30 seconds to reset system
Accuracy less than ±0.001MMDirt in the sensorRemove slider cover and its assembly, clean with compressed air 5KG/CM2
No display on LCD

1.Improper battery position

2.Low battery

1.Remove battery cover and check battery position

2.Replace Battery


Hot Tags: electronic digital cailiper, China, manufacturers, suppliers, price, brands